Bosch Therm 6000 O WRD 10-2 G Gas tankless water heater will pleasantly surprise you with its features:

  • Power modulation
  • Separate power and water flow control
  • Connects to an existing chimney
  • The heater switches on automatically when the tap is opened
  • The minimum required operating water pressure is 0.35 atm

 

Technical equipment

  • Ignition from the hydrodynamic generator Hydropower
  • Automatic maintenance of water temperature and flow rate when the water pressure in the water supply system changes
  • Ionization electrode for flame control
  • Temperature limiter to protect the heat exchanger from overheating
  • Draft control device with automatic column shutdown
  • Atmospheric gas burner made of stainless steel with the possibility of switching to LPG operation
  • Tin-free copper heat exchanger with a service period of 15 years

Properties

    Gas flow boiler

  • Energy efficiency class

    A

  • Nominal thermal power, min/max, kW

    7-17,4

  • Nominal thermal load, min/max, kW

    8,1–20

  • Permitted natural gas pressure, mbar

    13

  • Natural gas consumption, at maximum capacity, m3/h

    2.1

  • LPG consumption, at maximum capacity, kg/h

    1.5

  • Outlet water temperature, C

    35-60

  • Hot water flow at ΔT = 50 K, l/min

    2-5

  • Hot water flow at ΔT = 25 K, l/min

    4-10

  • Minimum working pressure, bar

    0.35

  • Flue gas temperature, at maximum capacity, °С

    160

  • Mass flow of flue gases at maximum power, kg/hour

    47

  • Weight (with packaging), kg

    11

  • Permitted pressure of liquefied gas (propane/butane), mbar

    30