0
Comprasion
Application
GC2300iW 24/30 / Condensing double-circuit boiler Condens
Energy-efficient solutions for buildings

Brand:
Bosch Home Comfort
How it works
This section contains information about the vendors and solutions presented on the platform. Once you have selected several solutions, you can compare them with each other or add them to your funding application.
About solution
Gas wall-mounted condensing boiler for heating and hot water supply will pleasantly surprise you with its features:
- Hot water is produced in a plate heat exchanger by the flow-through method
- A closed combustion chamber boiler with forced flue gas extraction can be installed indoors regardless of the presence of a chimney
- Infinitely variable automatic power control in heating and hot water mode
- LCD with operating parameters and standard error codes facilitates set-up and maintenance
- Operation control via room controllers and function modules via EMS BUS
- Possibility of wireless connection to EasyControl with Control Key network coordinator
Technical equipment
- Stainless steel burner with pre-mixing
- Ionization electrode for flame control
- Draft control device with automatic boiler shutdown
- Temperature limiter that protects the heat exchanger from overheating
- Built-in heating pump with energy-saving mode
- Infinitely variable modulated fan with speed control sensor
- Exhaust of combustion products and supply of combustion air through coaxial flues Ø60/100 or Ø80/125
- Possibility of connection to a “warm floor” system
- HMI 300 control panel with display of operating modes and standard error codes for setup and operation
Properties
-
Energy efficiency class in heating mode
A
-
Energy efficiency class in DHW mode
A
-
Nominal heating output, kW
3,4 – 25,2
-
Nominal heat output of hot water, kW
3,0 – 29,4
-
Range of operating temperatures in heating mode, °C
30-82
-
Volume of the expansion tank, liters
6
-
Water temperature in the DHW circuit, °C
35-60
-
Maximum permissible pressure of the heating system, bar
3
-
Maximum permissible pressure in the DHW circuit, bar
10
-
Minimum permissible pressure in the DHW circuit, bar
0.3
-
Natural gas consumption, at maximum capacity, m3/h
3.05
-
LPG consumption, at maximum capacity, kg/h
2.21
-
Flue gas temperature at the boiler exit, °С
69
-
Mass flow of flue gases at maximum power, kg/hour
47.9
-
Diameter of the flue pipe, mm
60/100, 80/80, 80/125
-
Weight (with packaging), kg
36
-
Nominal thermal load in heating mode, kW
3,1-24,5
-
Nominal thermal load of DHW, kW
3,1-30,0